5. During the whole process of use, good contact should be maintained between the lamp cap and the contact point of the lamp, otherwise the lamp cap will be seriously oxidized, resulting in the burst of the lamp tube seal.
Sixth, the UV lamp must be in a cooling state to start. ;When starting again, wait until the UV lamp is completely cooled before starting, after 5 minutes ;, the more frequent the switching times, the shorter the lamp life
7. The average lifespan of the high-pressure mercury lamps in Xinguang Lighting Factory is 00-1000 hours, and the surface temperature of the lamps is 600-700 degree during normal operation. Mainly related to the number of lamp starts.
8. It is strictly forbidden for lamps and transformers to work in an overloaded state, so as to avoid lamp explosions or transformer burning accidents. The power supply voltage should not fluctuate too much. If it suddenly drops by more than 5 percent , it may cause self-extinguishing. If the lamp cap is burned out and the lamp tube bursts, it is not the inherent quality of the lamp tube, it is purely improper use, and will not be returned.
9. The transformer must have good natural ventilation conditions for heat dissipation.
185nm Ozone or 254nm Ozone free UV light UVC 25W Lamp GPH550T5 UVC germicidal bulb for air conditioner system sterilization.:
Product name: UVC germicidal bulb
Warranty(Year): 1-Year
Lifespan (hours): 10000
Certificate: CE ROHS
Voltage: 110V-240V
Light Source: Quartz Tube